Revolving door-H 104.01
Together with the casing, this metal revolving door represents one of the basic elements to construct clean workplaces and areas with maximum safety, sterility, hygiene, easy maintenance and sanitation.
PRODUCT DESCRIPTION
Facing
- The facing of the door leaf consists of a molded tile produced by precision molding.
- Reinforcements are glued-in along the perimeter of the facing, in order to increase the rigidity of the door leaf.
- Reinforcement and filler are glued together under pressure.
Door wing
- The door leaf is solid or glazed with the PHARMA system, offering double-sided glazing where the glass pane is in plane with the surface of the door leaf.
- It is possible to install blinds in the space between the glass panels.
Casing
- Mounting into the partition.
- Casing is in line with partition.
1) Casing
|
ADVANTAGES
- Magnetic locks - tongue extends until closing and no damage to casing the paint.
TECHNICAL DATA
Door type |
---|
basic hinged door H |
Swing direction |
---|
left |
right |
Finish |
---|
single wing |
double wing |
Door dimensions |
---|
1100x2010 |
1300x2010mm (active wing width 900mm) |
1500x2010mm (active wing width 900mm) |
1700x2010mm (active wing width 900mm) |
700x2010 |
900x2010 |
In the case of an atypical active door wing, it is necessary to specify the dimensions of the active wing as part of the code. For example 1800/900/x2010 (clear width 1800, active wing 900, passive wing 900). |
Door thickness | |
---|---|
thickness | value |
42 mm | for partition 52 mm |
Grounding for zone I and II |
---|
Earthing for zone I and II |
Earthing has not been done |
Atypical |
Hinge type |
---|
Dr. Hahn |
Atypical |
In the case of a different hue of the casing, the hinge is automatically of the same hue as the casing. Atypical finish - the customer requires a different hue than the casing - according to RAL colour standard. |
Glazing size |
---|
usual glazing 400x920 |
solid door without glazing |
atypical |
The atypical dimension of the glazing should be noted in the note. In the case of double doors, only the active wing will be glazed. |
Glazing glass type |
---|
laminated safety glass, thickness 6 mm |
mirror glazing 2/3 on side of hinge 400x1450mm |
mirror glazing on opposite side of hinge 400x1450mm |
atypical |
Mirror size 400x1450 mm for all door dimensions. |
Blinds type |
---|
without blinds |
magnetic blinds |
mechanical blinds |
atypical |
Standard hue of blinds S156 (silver) according to the manufacturer's sample book, custom hues according to RAL colour standard. |
Blinds location |
---|
on side of hinges |
on opposite side of hinges |
HVAC grille |
---|
without HVAC grille |
grille 400x400 (VPR+VPK) |
atypical |
Standard colour finish is the colour of the door wing. |
Type of door control |
---|
automatic operator |
manual |
door closer |
atypical |
Warning - in the case of double wing door with self-closers on both wings, the door closing coordinator shall be specified. |
I. Hardware - on the side of hinges |
---|
handle |
fixed doorknob |
elbow switch (S10-E) |
one-point panic exit push device |
sensor switch (clean switch) |
button (S10-E) |
operable doorknob |
stainless steel plug |
not included in delivery |
atypical |
II. Hardware - on the opposite side of hinges |
---|
handle |
fixed doorknob |
elbow switch (S10-E) |
one-point panic exit push device |
sensor switch (clean switch) |
button (S10-E) |
operable doorknob |
stainless steel plug |
not included in delivery |
atypical |
Cylindrical insert |
---|
openings for lock and insert have not been cut out |
standard cylindrical insert |
not included in delivery |
atypical |
For S10-E it is always C0 - the opening is not cut out. |
Drop seal |
---|
Dropseal ELLEN MATIC 2K |
without strip |
atypical |
Protective bumper, kick plate - dimensions and finish must be specified in the notes to the door order. |
Casing mounting |
---|
finish for a plasterboard wall (HSE) |
finish for a double partition |
finish for partition panels |
finish for Surgical |
atypical |
When ordering door frames type "H" in the company HSE, it is necessary to state in the order: Door frames H DZD for FOR CLEAN |
Casing thickness |
---|
52 mm |
100 mm |
145 mm |
in the case using of the additional 25 mm column MS-156, it is necessary using of notes: 1 - additional column on the hinge side 2 - additional column on the opposite side of the hinges |
Indication |
---|
Without indication |
with indication on the right on side without hinges SP-OZ |
with indication on the right on side of hinges SP-PZ |
with indication on the left on side without hinges SL-OZ |
with indication on the left on side of hinges SL-PZ |
with double-sided indication on the left SP-O/P |
with double-sided indication on the right SP-O/P |
atypical |
Door wing blocker |
---|
without el. blocker |
electromechanical solenoid lock ST-DB 100 |
atypical |
Facing hue and material |
---|
Galvanized metal sheet, hue RAL 9016 |
Stainless steel AISI 304 |
Powder coating (Komaxit), hue RAL |
RAL anti-bacterial varnish |
atypical design |
In the case of different door wing facings, it is necessary to specify the hue as atypical, and to provide more details in the notes. |
Casing hue and material |
---|
Galvanized metal sheet, powder coating (Komaxit), hue RAL 9016 |
Stainless steel AISI 304 |
Galvanized metal sheet, powder coating (Komaxit), hue RAL |
RAL anti-bacterial varnish |
Atypical design |
---|
Type design |
Atypical design |
Type design 0 - Unique specification out of offered versions Atypical design Q - atypical design that cannot be uniquely specified by a code |